Internal face, external face: what RICS actually measures
Two plans of the same property can print different areas and both be correct. The difference is usually not accuracy; it is the measuring basis, and the basis is set by the standard the plan was drafted to.
Where the line sits
RICS, with IPMS built into it, works from the internal face of the walls — the surface you would touch standing inside the room. Anything measured to the outside of the structure will read larger, because it includes the wall itself.
What this means on the drawing
- Room areas are the usable space inside each room, not the footprint the room occupies in the building.
- Wall thickness appears on the drawing but is not counted into room area.
- Totals will not match a developer brochure quoting a gross external figure, and that is expected.
When it matters most
Apartments and terraced houses, where party walls are thick and a small percentage of the total. On a compact flat the gap between internal and external figures is large enough that buyers notice it — which is the argument for saying on the listing which standard the plan follows.